SOT-GS50/80/150 Series
Feature
Model No. Descriptions
Sample System Configuration of SOT-GS50/80 Series
Specifications
Model
|
SOT-GS501A/B
SOT-GS502A/B SOT-GS508A/B |
SOT-GS801A/B
SOT-GS802A/B SOT-GS808A/B |
SOT-GS1501A/B
SOT1502A/B SOT1508A/B |
Rated supply voltage
|
12/24VDC, 10% or less voltage ripples
|
||
Operating supply voltage
|
10-30VDC, peak voltage not higher than 30V including ripples
|
||
Power consumption
|
3W MAX
|
||
Transmission distance
|
0 – 50m
|
0 – 80m
|
0 – 150m
|
Angle of spread
(horizontal/vertical) |
2°
Initial values at maximum transmission distance |
1.5°
Initial values at maximum transmission distance |
|
Data format
|
Serial/serial
|
||
Transmission method
|
Full-duplex, bi-directional
|
||
Baud rate
|
DC – 38.4kbps
|
||
Modulation method
|
FSK
|
||
Lighting element
|
Near infrared light emitting diode
|
||
Wave length of emitted light
|
870mm
|
||
Receiving element
|
Photo diode
|
||
Signal interface
|
RS232C RS422
< GS508/808/1508 Only > – RS485 Transmission delay time: ([1/( transmission speed bps)] x 25.6) sec Example: If the transmission speed is 2,400 bps, the transmission delay time is about 11 ms. |
||
Multi-drop connectable units
|
< GS508/808/1508 Only > Up to 20
|
||
Auxiliary output
|
CDO output : “ON” when the communication is permitted.
ALM output : “OFF” when the reception level is low. Output type : Photo coupler insulated NPN open collector outputs Output rating : 30VDC, 50mA max. Residual voltage with the output transistor on is 2V or less. |
||
Power/signal connector
|
25-pin D-shaped sub-connector (socket terminal)
|
||
Power connector
|
3-pin metal connector (pin terminal)
|
||
Indicators
|
POW (Power indicator lamp) : Lights up red when the power supply is on.
CD (clear data indicator lamp) : Lights up red at a sufficient reception level for communication. LEVEL (reception level indicator lamp (2) ) : Lights up green according to the reception level. SD (send data indicator lamp) : Lights up red when the sending data input is on. RD (receive data indicator lamp) : Lights up green when the received data output is on. |
||
Check terminals
|
DC voltage corresponding to the reception level is provided.
(Use the DC voltage range with a 10kOhm /V or higher tester) |
||
Ambient operating temperature
|
-10 – +50°C No freezing temperatures allowed.
|
||
Ambient operating humidity
|
40 – 85% RH or less No condensation allowed.
|
||
Ambient operating illumination
|
10,000lx or less for incandescent and fluorescent lamps
No externally disturbed light shall directly enter the receiver. |
||
Vibration resistance
|
10 to 55Hz in frequency, 1.5mm in complex amplitude and 5minutes for
sweep 20 cycles in each of X, Y and Z directions (per JIS C0040) |
||
Shock resistance
|
500m/s2, 10 cycles in each of X, Y and Z directions (per JIS C0041)
|
||
Enclosure rating
|
IP40
|
||
Outside dimensions
|
80 (W) × 110 (D) × 40 (H) Main unit only.
|
||
Weight
|
Approx. 250g. Main unit only.
|
||
Accessories
|
2 fixtures/set
|
||
Options
|
Power/signal connector : 25-pin D-shaped sub-connector (plug terminal)
Power connector : 3-pin metal connector (socket terminal) |