Power supply voltage |
24V DC  10%
Power ripple 10% or less |
Current consumption |
100mA MAX. at 24V DC |
Serial
interface part |
I/F Type |
Compliant with RS422 |
I/F Signals |
a. RD : Received data input
b. CD : Carrier detection input
c. SD : Send data output
d. TC : Transmission clear output |
Transmission method |
Full-duplex or half-duplex bi-directional
Selectable with function setting switch |
Serial data format |
a. Synchro method : Start/Stop synchronization
b. Data length : 8bit
c. Start bit : 1bit
d. Stop bit : 1bit
e. Parity : Even number
f. Assay method : Parity check and check sum |
Data transmission rate |
600/1200/2400/4800/9600/19200/38400/76800
bps
Selectable with function setting switch
In the wireless transmission by means of SOT, transmission rate
become restricted by the transmission rate of SOT to be used. |
Parallel
I/F part
*Exclusive of delay in response time when transmission is synchronized
and parallel I/F. |
Power supply |
To be supplied from terminal block
for parallel I/F |
Input signal numbers |
32 points(It can extend up to 128
points maximum when 3 subunits are added) |
Input circuit |
Isolation method : Photo coupler
insulated input (Sink type)
Rated input voltage : 12/24V DC
Rated input current : Approx. 3/5mA
Leakage current at OFF : 1.2mA or less (At 24V DC)
*When using two wire system proximity switch, check the leakage
current at OFF.
Working voltage range : 10.2 to 26.4V DC
(Ripple rate : 5% or less)
Input resistance : Approx. 5k Ohm
Delay in response time : OFF to ON 1ms Max.
ON to OFF 1ms Max. |
Output signal numbers |
32 outputs (It can extend up to
128 points maximum when 3 subunits are added) |
Output circuit |
Isolation method : Photo coupler
insulated output (Sink type)
Emitter common (32 points/1 common)
Working load voltage range : 4.5 to 30V DC
Load current : 0.1A Maximum/1 point
Simultaneous ON current : 1.0A Maximum/32 points
Surge killer : Clamp diode
Delay in response time : OFF to ON 1ms Maximum
ON to OFF 1ms Maximum |
Transmission time |
Transmission rate
|
Transmission method
|
Signal channel No |
32 points |
64 points |
96 points |
128 points |
| 600 bps
|
Half-duplex |
475 ms |
697 ms |
919 ms |
1141ms |
Full-duplex |
327 |
475 |
623 |
771 |
| 1200 bps |
Half-duplex |
253 |
364 |
475 |
586 |
Full-duplex |
169 |
244 |
319 |
394 |
| 2400 bps |
Half-duplex |
128 |
185 |
242 |
299 |
Full-duplex |
88 |
126 |
162 |
199 |
| 4800 bps |
Half-duplex |
72 |
101 |
130 |
159 |
| Full-duplex |
47 |
66 |
85 |
104 |
| 9600 bps |
Half-duplex |
38.5 |
54 |
69.5 |
85 |
Full-duplex |
28 |
37.5 |
47 |
56.5 |
| 19200 bps |
Half-duplex |
25 |
33.5 |
42 |
50.5 |
| Full-duplex |
17.5 |
23 |
28.5 |
34 |
| 38400 bps |
Half-duplex |
12.6 |
17.4 |
22.5 |
27 |
| Full-duplex |
7.0 |
10.5 |
14 |
17.5 |
| 76800 bps |
Half-duplex |
10.5 |
14 |
17.5 |
21 |
| Full-duplex |
4.7 |
6.6 |
8.5 |
10.5 |
Control I/F |
Input signal |
a. CTL (Control) |
OFF : Normal operation
ON : Transmission stop Sent data +SD "H", -SD "L"
Transmission stop +TC "H", -TC "L"
Parallel output All points OFF
RCV output OFF DT output OFF |
b. TCD
(Transmission stop) |
OFF : Normal operation
ON : Transmission stop
Sent data +SD "H", -SD "L"
Transmission stop +TC "H", -TC "L"
Receiving is in normal operation
*Effective at full-duplex only |
c. M/S
(Switching between master and slave) |
OFF : Master Priority on sending
ON : Slave Priority on receiving
* Effective at half-duplex only. |
Input circuit |
Identical specification with parallel
I/F |
Output signal
|
a. RCV
(Receiving synchronization) |
Stays "ON" while receiving
data from other S/P converter (Operation equal to CD signal of
SOT) |
b. DT (Data normal) |
Comes ON when something is wrong
such as corruption of data with the data received from other S/P
converter.
When something is wrong with received data, this converter stays
"OFF" before data is normal again. |
c. ALM
* 1. (Reception level alarm) |
Comes "OFF" when reception
level of SOT to be connected lowers. |
d. CDO
* 1. (Reception) |
Comes "ON" when reception
level of SOT to be connected normal.
* 1. ALM and CDO output become effective when the connection of SOT-GS50/80/150
series. |
Output circuit |
Identical specification with parallel
I/F. |
External connection |
Serial I/F |
D-bus connector 15-pin
XM2A-1501 (Pin connector) OMRON make or equivalent
XM2S-1511 (Hood) OMRON make or equivalent |
Parallel I/F |
Flat cable connector 40-pin
FCN-365P040-AU FUJITSU make or equivalent |
Power/control I/F |
Terminal block 9-pole
Addition of subunit Flat cable connector 14-pin
HIF3BA-14PA-2.54DS Hirose make or equivalent |
Power for parallel I/F |
Terminal block 2-pole |
Setting the transmission
conditions |
Addition Numbers setting switch (Rotary switch) |
This switch allows you to set the
number of subunits to be added. |
Function setting switch (4bit DIP switch) |
This switch allows you to set following
functions :
a. Switching of transmission method 1 bit
b. Switching of serial transmission rate 3 bits |
Monitor indicator
lamp (Red and green LEDs)
* For I/O numbers 1 through 16 (17 through 32), I/O indication
becomes 0 through 9 and A through F. |
1. Power indicator lamp (Red, green) |
You can check the equipment status
through Power indicator lamp.
POW 1 point |
2. Receiving indicator lamp (Red) |
RCV 1 point |
3.Serial send data indicator lamp (Red) |
SD 1 point |
4. Serial receiving data indicator lamp (Red) |
SD 1 point |
5. Parallel input indicator lamp *2 |
IN 32 points
Inputs 1 to 16 : Red LED17 to 32 : Green LED |
6. Parallel output indicator lamp *2 |
OUT 32 points
Outputs 1 to 16 : Red LED
17 to 32 : Green LED
*2 For I/O numbers 1 through 16 (17 through 32), I/O indication
becomes
0 through 9 and A through F. |
Weight |
Approx. 660g (Main part) |
Accessories |
Connector for serial I/F For body
side 1 set
Crossover for power Red and blue 1 each |
Options |
1. Cable with connector for parallel
I/F SOT-FB harness
2. Cable with connector for addition of subunit SPC-X 
harness
 :
1 For addition of 1 subunit
 :
2 For addition of 2 subunits
 :
3 For addition of 3 subunits |