Model |
SOT-NP401H/S  |
SOT-NP403H/S  |
SOT-NP801H/S  |
SOT-NP803H/S  |
Rated power voltage |
DC12/24V Ripple 100 mVp-p or less |
Power voltage
used |
DC10 - 30V Ripple 100 mVp-p or less |
Consumable current |
60mA MAX |
Transmission distance |
0 - 1m |
0.1 - 3m |
0 - 1m |
0.1 - 3m |
Direction angle |
30
|
5 |
30 |
5 |
Transmitting points |
Input 4-bit/Output 4-bit 
|
Input 8-bit/Output 8-bit |
Transmission method |
Half-duplex 2-way and 1-way direction |
Detecting method |
Bit reverse any time comparison
method |
Transmitting time |
15ms MAX (M/S mode)  20ms
MAX (X mode) |
Projecting element |
Short-wave-length infrared LED |
Receiving element |
Photo transistor |
Modulation method |
Pulse modulation 45 KHz |
Input date points |
4 points
|
8 points |
input model Photo-coupler insulation
type (Sink input)
Input signal Contact-point or Open collector
Input voltage DC10 - 30V However, input voltage is the line-to-line
voltage
between EXT+V and IN
Input current 4  0.5mA
(in DC 24V) However, the residual voltage when turned On is below
than 2V. The leakage current when turned Off is below than 0.5mA. |
Output date points |
4 points |
8 points |
Output model Non-insulation model
Open collector output by NPN transistor (Sink Output)
Load voltage DC4.5 - 30V
Load current 100mA per point The residual voltage when output
turned On Should be below than 1.5V and total load current Below
than 500mA |
Indicators |
POW display: Lights up (red) when power is on
CTL/TCD display: Lights up (red) when CTL input is on/lighted (green) when
TCD input is on
Lighted
DT/RCV display: Lights up (red) during successful data reception/lighted
(green) during stable optical reception
IN display: Lights up (red) when data input is on
OUT display: Lights up (green) when data output is on
When the RCV display (green) is lighted , the DT display (red)
will also be lighted . |
Connection |
With attached 1-m cable 18C 
0.14mm 2 (AWG26)
With attached 1-m cable 26C 
0.14mm 2(AWG26) |
Ambient operating temperature |
-20 - +50  C
No freezing temperatures allowed. |
Ambient operating humidity |
40 - 85% RH No condensation allowed. |
Ambient operating illumination |
4,000lx or less for incandescent
and fluorescent lamps
No externally disturbed light shall directly enter the receiver. |
Vibration resistance |
10 to 55Hz in frequency, 1.5mm in
complex amplitude and 5minutes for sweep
20 cycles in each of X, Y and Z directions |
Shock resistance |
500m/s2, 20 cycles in each of X,
Y and Z directions |
Enclosure rating |
IP66 |
Outside dimensions |
60mm (W) 
50mm (D) 
22mm (H) |