Model |
SOT-MQ160A/B |
SOT-MQ80A/B |
Environment |
CC-Link |
Transmission rate |
156k, 625k, 2.5Mbps |
Power voltage |
Rated voltage:24VDC  Power
ripples:10% or less Voltage:18-30VDC Peak voltage including ripples:
Within 30V |
Current consumption |
Less than 150mA(at 24VDC input) |
Interface |
RS485 compliant |
Transmission method |
Half duplex |
Communication control method |
Bit forward |
Num. stations occupied |
When monitor function used: 1 When
monitor function not used : 0 |
Transmission distance |
0.2 - 160m |
0.2 - 80m |
Directivity |
1 degrees (both horizontal and vertical) |
Modulation method |
FSK |
Lighting element |
Near infrared light emitting diode(light
emitting wavelenghth 870nm) |
Receiving element |
Photodiodes |
Setting switches |
4-pin dip switch
SW1,2 : Communication speed setting
Communication speeds 156k, 625k, 2.5M Cannot be set
SW3 : Not used Use
with this set to "off"
SW4 : Switch transmission carrier frequency OFF CH1 ON CH2 |
Auxiliary output |
CDO : "ON" when communication
is permitted
ALM : "OF" when the reception level is low |
Photocoupler insulation NPN
open collector output |
Output rating : 30VDC 50mA MAX |
Connection |
For signal :4-pole connector terminal
block
For power/auxiliary output: 5-pole connector terminal block |
Check terminals |
DC voltage corresponding to the
reception level is provided.
(Use the DC voltage range with a 10kOhm /V or higher tester) |
Code setting switch |
Two rotary switches
00 : Monitor function not used
01 to 64 : Code setting when monitor function used
65 to 99 : Cannot be set |
Terminal resistance switch:
Three-position slide switch
|
ON1 : 110 Ohm
OFF : Open
ON2 : 130 Ohm |
Ambient operating illumination |
Solar beam: 10,000 lx or less
Fluorescent, incandescent lamps: 3,000 lx or less
No externally disturbed light shall directly enter the receiver. |
Ambient operating temperature |
-10 - +55  C
No Freezing allowed |
Ambient operating humidity |
10 - 85% RH No condensation allowed |
Weight (Main body) |
350g |
Accessories |
Fixture (1 Set), screws for fixture
(4 pcs.).
Signal plug (1 pc), power/aux. output plug (1 pc). |