Detecting
method |
Translucent type |
Light source |
Infrared LED |
Emission wavelength |
940nm |
Number of elements |
18 |
Number of scanning
optical axes |
Max. 84 |
Element interval |
Lower 4 elements: 58.5 mm on average,
upper 15 elements: 117 mm on average |
Lowest optical
axis |
15 mm from bottom end of case |
Detection width |
1,829 mm, from bottom end of case
to topmost element |
Setting distance |
0~3m (10°C 
Ta  +40°C)
0~2.5m (-10°C 
Ta  +50°C) |
Power supply voltage |
DC 24 V + 10%, -20%, power supply
ripple 10% |
Power consumption |
Projector:1.5W or less, receiver:
2 W or less |
Control
output |
Circuit type |
NPN transistor open collector output |
Rating |
100 mA or less, resistance load,
with over-current protecting function
Voltage drop at output "ON" - 2 V MAX.
Leakage current at output "OFF" - 100 
A MAX. |
Operation mode |
Control output "ON" when
receiving total optical axes |
Response time |
At detecting: 80 ms MIN. (Main scan)/400
ms MAX. (Other than main scan)
At reset: 400 ms MAX. |
Holding time |
150ms MIN |
Time-out
function |
Optical axis cut-off function at
failure of sensor
Condition: When the same optical axis has been shielded longer
than the time-out setting value |
Tolerance |
Adaptable up to 5 optical axes (elements),
which do not adjoin each other |
Setting time. |
Approx. 45 sec |
External connection |
Extension of flexible cable length:
6 m (-6) or 10 m (-10) |
Ambient operating illuminance |
5,000 lx or less for fluorescent
lamp. Direct incident light to receiver not allowed.
100,000 lx or less for sunlight. Direct incident light to receiver
not allowed.
50,000 lx or less where sunlight irradiates directly receiver. |
Enclosure rating |
IP54 |
Weight |
Projector/receiver: Approx. 0.7